    In This Topic

    Before installing anything... Sample Install1

    For this sample:- Sample Install2
    1. Ensure that the hardware lock with Automation Server software is plugged in.
    2. Turn off "Use simple file sharing" Sample Install3
    3. Install Automation Server to c:\AllMasterSoftware\AutomationServer.
      Browse and set destination...
      Sample Install4
    4. Setup the Client
      Sample Install5
    5. Install Automation Server.
      Sample Install6
    6. Now check permissions.
      The Print Queue Manager shortcut is in the Client Setup folder....
      Sample Install7 [Note: we have made a copy of the .reg file and substituted the full local spool path (with \ changed to \\) so that we can merge into the server and use it as a client also, see client setup later]
    7. Double clicking on the Print Queue Manager shortcut initially gives this error...
      Sample Install8

      Here is the folder before adding permissions...
      Sample Install8a
    8. Click on the "Add..." button.
      Sample Install9
    9. Click on 'Locations...' and change the location to 'this computer'...
      Click 'OK'
      Sample Install9
    10. The following dialog will be presented. Click 'Find Now' button...
      Press 'OK'. The 'Select Users or Group' will be presented, shown right...
      Sample Install9 and 'OK' again...
    11. Notice the 'Internet Guest Account' does not have Write access.
      Give it full access and click 'OK'
      Sample Install11
    12. Then try the Print Queue Manager again...
      It should show that this is now working.
      Sample Install12

    Client Setup

    Next setup all the workstations (and also the server if you want to use it occasionally as a client). Until you do this, Automation Server is greyed out on the CabMaster File menu... To fix this on a workstation, you just need to...
    1. use a copy of the QPClient.reg file in the AutomationServer\Client Setup folder.
      • If you want to occasionally use the server itself as a client you need to
      • change the ServerSpoolPath from P: to the local path.
      • either edit this directly using regedit,
      • or if you want to set up a .reg file to do it, make sure to replace \ by \\ everywhere in the path.
    2. Clients need to have P: mapped to the server spool path on the server, and must be able to write there.

    Starting the Server

    Double click on QPServer.exe in the AutomationServer folder to start the server. You get this message...
    Sample Install13 The server is now running and displays this dialog
    Sample Install14